1 : Coast to Stop
The output turns off and the motor coasts to stop. The output terminal set for
Fault [H2-01 to H2-03 = E]
activates.
2 : Fast Stop (Use C1-09)
The drive stops the motor in the deceleration time set in
C1-09 [Fast Stop Time]
. The output terminal set for
Fault
[H2-01 to H2-03 = E]
activates.
3 : Alarm Only
The keypad shows
oS
and the drive continues operation. Only use this setting in special conditions to prevent
damage to the motor and machinery. The output terminal set to
Alarm [H2-01 to H2-03 = 10]
activates.
Note:
•
When
A1-02 = 0 [Control Method Selection = V/f]
, set
H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F
Control)]
to enable this parameter.
•
When
A1-02 = 6 [Control Method Selection = AOLV/PM]
, the drive will automatically set
F1-03 = 1 [Coast to Stop]
. You cannot
change this value.
■
F1-04: Speed Deviation Detection Select
No.
(Hex.)
Name
Description
Default
(Range)
F1-04
(0383)
Speed Deviation Detection
Select
Sets the method to stop the motor or let the motor continue to operate when the drive detects
dEv
[Speed Deviation]
.
3
(0 - 3)
When the difference between the frequency reference and the motor speed is more than the value set in
F1-10
[Speed Deviation Detection Level]
for longer than the time set in
F1-11 [Speed Deviation Detect DelayTime]
, it
will trigger
dEv
.
Note:
When
A1-02 = 0 [Control Method Selection = V/f]
, set
H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)]
to enable this parameter.
0 : Ramp to Stop
The drive ramps the motor to stop in the deceleration time. The output terminal set for
Fault [H2-01 to H2-03 =
E]
activates.
1 : Coast to Stop
The output turns off and the motor coasts to stop. The output terminal set for
Fault [H2-01 to H2-03 = E]
activates.
2 : Fast Stop (Use C1-09)
The drive stops the motor in the deceleration time set in
C1-09 [Fast Stop Time]
. The output terminal set for
Fault
[H2-01 to H2-03 = E]
activates.
3 : Alarm Only
The keypad shows
dEv
and the drive continues operation. Only use this setting in special conditions to prevent
damage to the motor and machinery. The output terminal set to
Alarm [H2-01 to H2-03 = 10]
activates.
■
F1-08: Overspeed Detection Level
No.
(Hex.)
Name
Description
Default
(Range)
F1-08
(0387)
Overspeed Detection Level
Sets the detection level of
oS [Overspeed]
as a percentage when the maximum output frequency
is 100%.
115%
(0 - 120%)
When the motor speed is more than the value set in
F1-08
for longer than the time set in
F1-09 [Overspeed
Detection Delay Time]
, the drive will detect
oS
.
Note:
When
A1-02 = 0 [Control Method Selection = V/f]
, set
H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)]
to enable this parameter.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...