b3-03
(0193)
Speed Search
Deceleration Time
Sets the deceleration time during Speed Search operation. Set the length of time to
decelerate from the maximum output frequency to the minimum output frequency.
Note:
When
A1-02 = 8 [Control Method Selection = EZOLV]
, this parameter takes effect
only in Expert Mode.
2.0 s
(0.1 - 10.0 s)
b3-04
(0194)
V/f Gain during Speed
Search
Sets the ratio used to reduce the V/f during searches to reduce the output current during
speed searches.
Determined by o2-04
(10 - 100)
b3-05
(0195)
Speed Search Delay
Time
Sets the Speed Search delay time to activate a magnetic contactor installed between the
drive and motor.
0.2 s
(0.0 - 100.0 s)
b3-06
(0196)
Expert
Speed Estimation
Current Level 1
Sets the level of current that flows to the motor during Speed Estimation Speed Search
as a coefficient of the motor rated current. Usually it is not necessary to change this
setting.
Determined by o2-04
(0.0 - 2.0)
b3-07
(0197)
Expert
Speed Estimation
Current Level 2
Sets the level of current that flows to the motor during Speed Estimation Speed Search
as a coefficient of
E2-03 [Motor No-Load Current]
or
E4-03 [Motor 2 Rated No-Load
Current]
. Usually it is not necessary to change this setting.
1.0
(0.0 - 3.0)
b3-08
(0198)
Expert
Speed Estimation ACR P
Gain
Sets the proportional gain for the automatic current regulator during Speed Estimation
Speed Search. Also adjusts speed search responsiveness. Usually it is not necessary to
change this setting.
Determined by A1-02
and o2-04
(0.00 - 6.00)
b3-09
(0199)
Expert
Speed Estimation ACR I
Time
Sets the integral time for the automatic current regulator during Speed Estimation Speed
Search. Also adjusts speed search responsiveness. Usually it is not necessary to change
this setting.
Determined by A1-02
(0.0 - 1000.0 ms)
b3-10
(019A)
Expert
Speed Estimation
Detection Gain
Sets the gain to correct estimated frequencies from Speed Estimation Speed Search.
1.05
(1.00 - 1.20)
b3-14
(019E)
Bi-directional Speed
Search
Sets the direction of Speed Search to the direction of the frequency reference or in the
motor rotation direction as detected by the drive.
0 : Disabled
1 : Enabled
Note:
•
When
E9-01 = 0 [Motor Type Selection = Induction (IM)]
and
A1-02 = 0, 2, or 8
[Control Method Selection = V/f, OLV, or EZOLV]
, the default settings change
when the setting of
b3-24 [Speed Search Method Selection]
changes.
–
b3-24 = 1 [Speed Estimation]
: Refer to
.
–
b3-24 = 2 [Current Detection 2]
: 0
•
When
E9-01 = 1 or 2 [Permanent Magnet (PM), Synchronous Reluctance
(SynRM)]
and
A1-02 = 0 or 8 [V/f, EZOLV]
, refer to
When you set
A1-02
,
b3-24
, and
E9-01
, set
b3-14
.
Determined by A1-02
and b3-24
(0, 1)
b3-17
(01F0)
Expert
Speed Est Retry Current
Level
Sets the current level for the search retry function in Speed Estimation Speed Search as
a percentage where drive rated current is a setting value of 100%.
150%
(0 - 200%)
b3-18
(01F1)
Expert
Speed Est Retry
Detection Time
Sets the length of time that the drive will wait to retry Speed Estimation Speed Search
when too much current flow stopped the Speed Search.
0.10 s
(0.00 - 1.00 s)
b3-19
(01F2)
Speed Search Restart
Attempts
Sets the number of times to restart Speed Search if Speed Search does not complete.
3 times
(0 - 10 times)
b3-24
(01C0)
Speed Search Method
Selection
Sets the Speed Search method when you start the motor or when you restore power after
a momentary power loss.
Note:
•
When
A1-02 = 8 [Control Method Selection = EZOLV]
, the default setting
changes when the setting for
E9-01 [Motor Type Selection]
changes.
–
E9-01 = 0 [Induction (IM)]: 2
–
E9-01 = 1, 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]: 1
•
When you set
b3-24
, it will trigger the drive to initialize
b3-14 [Bi-directional
Speed Search]
. After you set
b3-24
, set
b3-14
.
1 : Speed Estimation
2 : Current Detection 2
2
(1, 2)
b3-25
(01C8)
Expert
Speed Search Wait Time
Sets the length of time the drive will wait to start the Speed Search Retry function.
0.5 s
(0.0 - 30.0 s)
b3-26
(01C7)
Expert
Direction Determination
Level
Sets the level to find the motor rotation direction. Increase the value if the drive cannot
find the direction.
1000
(40 to 60000)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...