The setting in
H5-25
to
H5-28
and the data in the specified holding registers are as follows.
–
H5-25
= 0044H:
U1-05 [Motor Speed]
= 60.00 Hz (6000 = 1770H)
–
H5-26
= 0045H:
U1-06 [Output Voltage Ref]
= 200.0 V (2000 = 07D0H)
–
H5-27
= 0042H:
U1-03 [Output Current]
= 50% of drive rated current (100% = 8192, 50% = 4096 = 1000H)
–
H5-28
= 0049H:
U1-10 [Input Terminal Status]
= 00H
When you rewrite the parameter value with the write command through the
H5-11 [Comm ENTER Command
Mode]
setting, you must use the Enter command to save and enable the contents of the changes. Refer to
Comm ENTER Command Mode on page 656
and
for more information.
Table 6.6 Message Example When Reading from More than One Holding Register/Reading the Indicated Register
Byte
Command Message
Response Message (When Normal)
Response Message (When There is a Fault)
Setting Data
(Hex.)
Setting Data
(Hex.)
Setting Data
(Hex.)
0
Slave address
01
Slave address
01
Slave address
01
1
Function code
5A
Function code
5A
Function code
DA
2
Starting No.
Upper
00
Register status
0F
Register status
0F
3
Lower
01
Data in holding
register 1
selected with
H5-25
Upper
17
Data in holding
register 1
selected with
H5-25
Upper
17
4
Data Quantity
Upper
00
Lower
70
Lower
70
5
Lower
02
Data in holding
register 2
selected with
H5-26
Upper
07
Data in holding
register 2
selected with
H5-26
Upper
07
6
Byte No.
04
Lower
D0
Lower
D0
7
First data
Upper
00
Data in holding
register 3
selected with
H5-27
Upper
10
Data in holding
register 3
selected with
H5-27
Upper
10
8
Lower
01
Lower
00
Lower
00
9
Next data
Upper
17
Data in holding
register 4
selected with
H5-28
Upper
00
Data in holding
register 4
selected with
H5-28
Upper
00
10
Lower
70
Lower
00
Lower
00
11
CRC-16
Upper
4F
Starting No.
Upper
00
Error code
02
12
Lower
43
Lower
01
CRC-16
Upper
E9
13
-
Data Quantity
Upper
00
Lower
6C
14
-
Lower
02
-
15
-
CRC-16
Upper
AC
-
16
-
Lower
D0
-
Note:
The number of bytes set in the command message set the data quantity × 2 during the command message.
Register status
bit 0
Data in register 1 selected with
H5-25
1: Successfully read the register
0: Register read error
bit 1
Data in register 2 selected with
H5-26
1: Successfully read the register
0: Register read error
bit 2
Data in register 3 selected with
H5-27
1: Successfully read the register
0: Register read error
bit 3
Data in register 4 selected with
H5-28
1: Successfully read the register
0: Register read error
bit 4
Not used
bit 5
Not used
bit 6
Not used
bit 7
Not used
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...