12.2 A: Initialization Parameters
466
YASKAWA
SIEPC71061753A GA500 Technical Manual
No.
Name
Optimal Value
L8-05
Input Phase Loss Protection Sel
1: Enabled
L8-07
Output Phase Loss Protection Sel
1: Fault when One Phase is Lost
L8-38
Carrier Frequency Reduction
1: Enabled below 6 Hz
L8-41
High Current Alarm Selection
1: Enabled
The drive saves the parameters in
as User Parameters.
Table 12.15 Parameters Saved as User Parameters with the Hoist Preset
User Parameter No.
Parameter No. Saved
Name
A2-01
A1-02
Control Method Selection
A2-02
b1-01
Frequency Reference Selection 1
A2-03
b6-01
Dwell Reference at Start
A2-04
b6-02
Dwell Time at Start
A2-05
C1-01
Acceleration Time 1
A2-06
C1-02
Deceleration Time 1
A2-07
C6-02
Carrier Frequency Selection
A2-08
d1-01
Reference 1
A2-09
d1-02
Reference 2
A2-10
d1-03
Reference 3
A2-11
E1-08
Mid Point A Voltage
A2-12
H2-01
Term MA,MB,MC Function Selection
A2-13
L1-01
Motor Overload (oL1) Protection
A2-14
L4-01
Speed Agree Detection Level
A2-15
L6-02
Torque Detection Level 1
A2-16
L6-03
Torque Detection Time 1
7 : Crane (Traveling)
The drive automatically sets the parameters in
for a traveling application.
Table 12.16 Optimal Settings for Traveling Applications
No.
Name
Optimal Value
A1-02
Control Method Selection
0: V/f Control
b1-01
Frequency Reference Selection 1
0: Keypad
C1-01
Acceleration Time 1
3.0 s
C1-02
Deceleration Time 1
3.0 s
C6-01
Normal / Heavy Duty Selection
0: Heavy Duty Rating
C6-02
Carrier Frequency Selection
2: 5.0 kHz (4.0 kHz for AOLV/PM)
d1-01
Reference 1
6.00 Hz
d1-02
Reference 2
30.00 Hz
d1-03
Reference 3
50.00 Hz
H1-05
Terminal S5 Function Selection
3: Multi-Step Speed Reference 1
H1-06
Terminal S6 Function Selection
4: Multi-Step Speed Reference 2
H2-01
Term MA,MB,MC Function Selection
37: During Frequency Output
H2-02
Term P1 Function Selection
37: During Frequency Output
L3-04
Stall Prevention during Decel
0: Disabled
L8-05
Input Phase Loss Protection Sel
1: Enabled
L8-07
Output Phase Loss Protection Sel
1: Fault when One Phase is Lost
L8-38
Carrier Frequency Reduction
1: Enabled below 6 Hz
L8-41
High Current Alarm Selection
1: Enabled
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...