![YASKAWA CIPR-GA50C series Скачать руководство пользователя страница 411](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765411.webp)
YASKAWA
SIEPC71061753A GA500 Technical Manual
411
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T1-12
(0BDB)
Test Mode Selection
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can
operate the motor with a light load attached after Stationary Auto-Tuning is complete,
enable this parameter.
Note:
You must first set
T1-10 = 0 [Motor Rated Slip Frequency = 0 Hz]
to enable this
parameter.
0 : No
1 : Yes
0
(0, 1)
T1-13
(0BDC)
No-load voltage
Sets the no-load voltage of the motor. When the no-load voltage at rated speed is
available, for example on the motor test report, set the voltage in this parameter. If the
no-load voltage is not available, do not change this parameter.
Note:
To get the same qualities as a Yaskawa 1000-series drive or previous series drive,
set this parameter =
T1-03 [Motor Rated Voltage]
.
T1-03 × 0.9
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
◆
T2: PM Motor Auto-Tuning
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T2-01
(0750)
PM Auto-Tuning
Selection
Sets the type of Auto-Tuning for PM motors.
0 : Manual Entry w/ Motor Data Sheet
1 : Stationary (Ld, Lq, R)
2 : Stationary (R Only)
4 : PM Motor Code Selection
5 : High Frequency Injection
0
(Determined by A1-02)
T2-02
(0751)
PM Motor Code
Selection
If the drive is operating an SMRD, SMRA, or SSR1 series Yaskawa PM motor, enter
the PM motor code in to align with the rotation speed and motor output.
Determined by A1-02
and o2-04
(0000 - FFFF)
T2-03
(0752)
PM Motor Type
Sets the type of PM motor the drive will operate.
0 : IPM motor
1 : SPM motor
1
(0, 1)
T2-04
(0730)
PM Motor Rated Power
Uses the units set in
o1-58 [Motor Power Unit Selection]
to set the PM motor rated
output power.
Determined by o2-04,
C6-01
(0.00 - 650.00 kW)
T2-05
(0732)
PM Motor Rated Voltage
Sets the rated voltage (V) of the motor.
200 V Class: 200.0 V,
400 V: 400.0 V
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
T2-06
(0733)
PM Motor Rated Current
Sets the rated current (A) of the motor.
Determined by o2-04
(10% to 200% of the
drive rated current)
T2-07
(0753)
PM Motor Base
Frequency
Sets the base frequency (Hz) of the motor.
87.5 Hz
(0.0 - 590.0 Hz)
T2-08
(0734)
Number of PM Motor
Poles
Sets the number of motor poles.
6
(2 - 48)
T2-09
(0731)
PM Motor Base Speed
Sets the motor base speed (min
-1
(r/min)).
1750 min
-1
(r/min)
(0 - 34500 min
-1
(r/min))
T2-10
(0754)
PM Motor Stator
Resistance
Sets the stator resistance for each motor phase.
Note:
This parameter does not set line-to-line resistance.
Determined by T2-02
(0.000 - 65.000 Ω)
T2-11
(0735)
PM Motor d-Axis
Inductance
Sets the d-axis inductance of the motor on a per phase basis.
Determined by T2-02
(0.00 - 600.00 mH)
T2-12
(0736)
PM Motor q-Axis
Inductance
Sets the q-Axis inductance of the motor on a per phase basis.
Determined by T2-02
(0.00 - 600.00 mH)
T2-13
(0755)
Back-EMF Units
Selection
Sets the units that the drive uses to set the induced voltage constant.
0 : mV/(rev/min)
1 : mV/(rad/sec)
1
(0, 1)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...