6-axis sensor gauge finger (optional)
Fig. 41696
The linear movement in X direction and the stopping process in
Z direction are identified by inductive path measurement sensors
and transferred to the control system.
The control system releases the press beam for bending only
once the workpiece rests properly against the sensor finger.
The stop block for small parts is screwed on to the existing
gauge fingers. Small parts on both the sensor fingers can thus
be stopped.
B579EN
2015-06-01
The most important assemblies
3
‐
13
Stop block for small parts
(optional)
Содержание BendMaster 150