1
Grease nipples
Grease nipple at the regripping station
Fig. 71107
Maintenance interval: Every 6 months
1. Shut down the machine properly, secure the MAIN SWITCH
and secure with a padlock.
2. Check the rack for damage.
3. In case necessary, lubricate the rack.
B579EN
2015-06-01
Lubrication
5
‐
9
106612:
Checking and lubricating the
rack