3. In case necessary: request Technical Service.
Regripping station
Maintenance interval: As needed
Means, Tools, Materials
■
If necessary: muffler (material no. 0137657)
The muffler must be cleaned when the suction power of the vac-
uum ejector is reduced. If the suction power is still not correct
after cleaning, the muffler must be replaced.
1
Silencer
Regripping station suction cup
Fig. 71049
1. Shut down the machine properly, secure the MAIN SWITCH
and secure with a padlock.
2. Screw out the muffler.
3. Blow out the muffler with compressed air.
or
Ø
Replace the muffler if it is severely soiled.
4. Switch on the system again in manual mode.
5. Check vacuum function at the regripping station.