3.
Compressed air supply
Note
The connection point is indicated on the installation plan using
this symbol.
The BendMaster needs a separate compressed air supply. The
compressed air connection may be flexible or may consist of a
fixed pipe to the BendMaster's optional switch cabinet.
Property
Requirement
Required pressure
6±1 bar (87±15 psi)
Air consumption (required volume
rate of flow according to ISO 1217
or DIN 1945)
Average: 2 - 8 m
3
/h (1.18 -
4.71 cfm)
Compressed air supply connected loads
Tab. 2-8
Property
Requirement
Min. nominal diameter of the sup-
ply line
13 mm (1/2")
Min. nominal diameter of the main
line
13 mm (1/2")
Length of the connecting line
No limit
Supply lines compressed air supply
Tab. 2-9
Property
Requirement
Quality
class
1
Recommendation
Dust-free
Maximum particle size:
15 µm
4
Air filter in front of the
system
Conden-
sate-free
Cooled down to +7°C
(+44.6°F) pressure
dew point
5
Cold dryer
Oil-free
Maximum oil content:
5 mg/m
3
4
Oil-free sealing screw-
type compressor with
active carbon filter
Compressed air properties at the tapping point
Tab. 2-10
1
ISO°8573-1; 2010 edition
B579EN
Compressed air supply - Version 10
2
‐
13
Compressed air supply
Compressed air supply
connected loads
Supply lines compressed air
supply
Compressed air properties
at the tapping point
Содержание BendMaster 150
Страница 1: ...Operator s manual BendMaster TruBend Cell 5000...
Страница 2: ......
Страница 3: ...Operator s manual BendMaster TruBend Cell 5000 Original operator s manual Edition 2015 06 01...
Страница 6: ...II Before you proceed 2015 06 01 B579EN...
Страница 16: ...0 10 Table of contents 2015 06 01 B579EN...
Страница 44: ...1 28 Disassembly and disposal 2015 06 01 B579EN...
Страница 251: ...Chapter 6 Maintenance Technical Service 1 Maintenance overview 6 2 B579EN 2015 06 01 Maintenance Technical Service 6 1...