Fig. 41441
Note
Reference the D axis
(see "Referencing the D axis", pg.
4. Press the blue button on the portable manual control unit for
the axis to be referenced.
5. Press the blue
Z3
button on the portable manual control unit.
An automatic reference trip of the regripping station to the
left reference switch at the parking position is started.
6. Press the blue
Z4
button on the portable manual control unit.
An automatic reference run of the regripping station to the
right-hand reference switch at the parking position is started.
Referencing the D axis
Conditions
■
Manual operating mode is active.
■
No error messages, i.e. green LED on the portable manual
control unit lights up (acknowledge error if red LED is on).
(see "Enabling conditions for operation modes", pg. 4
■
The BendMaster is ready for operation (pulse trigger switch
on the portable manual control unit has been pressed,
"BendMaster" icon is green).
1. Select the >
Position
>
Position
menu on the portable manual
control unit.
2. Press
Reference
.
B579EN
2015-06-01
Switching on and referencing the BendMaster
4
‐
41
Содержание BendMaster 150
Страница 1: ...Operator s manual BendMaster TruBend Cell 5000...
Страница 2: ......
Страница 3: ...Operator s manual BendMaster TruBend Cell 5000 Original operator s manual Edition 2015 06 01...
Страница 6: ...II Before you proceed 2015 06 01 B579EN...
Страница 16: ...0 10 Table of contents 2015 06 01 B579EN...
Страница 44: ...1 28 Disassembly and disposal 2015 06 01 B579EN...
Страница 251: ...Chapter 6 Maintenance Technical Service 1 Maintenance overview 6 2 B579EN 2015 06 01 Maintenance Technical Service 6 1...