N2HET Control Registers
855
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
High-End Timer (N2HET) Module
20.4.3 N2HET Current Address Register (HETADDR)
N2HET1:
offset = FFF7 B808h;
N2HET2:
offset = FFF7 B908h
Figure 20-58. N2HET Current Address (HETADDR)
31
16
Reserved
R-0
15
9
8
0
Reserved
HETADDR
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 20-18. N2HET Current Address (HETADDR) Field Descriptions
Bit
Field
Value
Description
31-9
Reserved
0
Reads return 0. Writes have no effect.
8-0
HETADDR
N2HET Current Address
Read: Returns the current N2HET program address.
Write: Writes have no effect.
20.4.4 Offset Index Priority Level 1 Register (HETOFF1)
N2HET1:
offset = FFF7 B80Ch;
N2HET2:
offset = FFF7 B90Ch
Figure 20-59. Offset Index Priority Level 1 Register (HETOFF1)
31
16
Reserved
R-0
15
6
5
0
Reserved
OFFSET1
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 20-19. Offset Index Priority Level 1 Register (HETOFF1) Field Descriptions
Bit
Field
Value
Description
31-6
Reserved
0
Reads return 0. Writes have no effect.
5-0
OFFSET1
OFFSET1 indexes the currently pending high-priority interrupt. Offset values and sources are listed in
Read: Read of these bits determines the pending N2HET interrupt.
Write: Writes have no effect.
Note:
In any read operation mode, the corresponding flag (in the HETFLG) is also cleared. In Emulation