SCI Interrupts
1334
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
Serial Communication Interface (SCI) Module
26.3.4 Error Interrupts
The following error detection features are supported with Interrupt by the SCI module:
•
Parity errors (PE)
•
Frame errors (FE)
•
Break Detect errors (BRKDT)
•
Overrun errors (OE)
If any of these errors (PE, FE, BRKDT, OE) is flagged, an interrupt for the flagged errors will be generated
if enabled. A message is valid for both the transmitter and the receiver if there is no error detected until
the end of the frame. Each of these flags is located in the receiver status (SCIFLR) register. Further
details on these flags are explained in SCIFLR register description.
The SCI module supports the following 7 interrupts as listed in
(1)
Offset 1 is the highest priority. Offset 16 is the lowest priority.
Table 26-1. SCI Interrupts
Offset
(1)
Interrupt
0
Reserved
1
Wakeup
2
Reserved
3
Parity error
4
Reserved
5
Reserved
6
Frame error
7
Break detect error
8
Reserved
9
Overrun error
10
Reserved
11
Receive
12
Transmit
13-15
Reserved