12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide
73
Installing the TSG-3800
Input/Output Adapter Panels
Making Output Signal Connections
The output signals are available at the 50-contact connectors, J2 through J10, on a
19-inch rear panel and J2 through J12 on a 23-inch rear panel. Tip and ring contact
pairs are on opposite contacts (Ring = 1-20 and Tip = 26-45). Contacts 21 through
25 and 46 through 50 are shield grounds. Refer to
Chapter 7, Output Modules
, for
additional connection details for the specific Output modules being used.
Installing Modules
The first three slots in the TSG-3800X, starting from the left, must be covered with
blank filler panels (item number 10977120-000-0). Insert Output modules starting
with the fourth slot, in matched pairs. Therefore, slots 4 and 5 must contain identical
Output modules, slots 6 and 7 must contain identical Output modules, slots 8 and 9
must contain identical Output modules, and so forth. To properly install these
modules, refer to
Installing Modules
, on page 63.
Input/Output Adapter Panels
A variety of connector panels are available to adapt the 50-pin input/output (I/O)
connectors on the TSG-3800 series shelves to individual wire-wrap or balun
connectors for attaching to the customer’s system.
Note:
Distribution panels can be located at various distances from the
shelf depending on the type of output signal being used. See
Table
2-11
for signal type and the maximum cable length you can use when
installing distribution panels.
Table 2-11. Distribution Signal Maximum Cable Length
Output Signal
Maximum Cable Length
T1
655 feet
E1
655 feet
CC
1500 feet
RS-422
150 feet