12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 377
TL1 Reference
Autonomous Reports
<condtype> is the event number correlating to the event. Alarm events use number
1 through 32; all others are non-alarm events.
Table C-3
describes the condition
types for alarms and events.
<condtype> has one or more optional descriptors called <condscr>, which is a text
string that describes the alarm or event, as listed in
Table C-4
.
Table C-3. Condition Types
Condition Type
Description
AIS, BPV, CRC, LOS, OOF, SQL
Input signal faults
MTIE, TDEV, FREQ, PHA, REF
Input signal limits
INTIFCFAIL
Equipment faults
For the SBC firmware build:
INTIFCFAIL = CLK, FG, T1, OTP
OPER, MSG
Operator responses
ADDED, RESTORED, REMOVED
Module operations
ALARM, PWR, BUS
CPU Alarm operation
NA
Non-alarm event
Table C-4. Condition Descriptors
Condition Descriptor
Text
Description
srveff
SA, NSA
Service Affecting or
Not Service Affecting
montype
PHA, FREQ, MTIE, TDEV
Type of monitor data
tmper
xHR or ySEC
Time period in hours or
seconds
ocrdat
YY-MM-DD
Date of occurrence
ocrtm
HH-MM-SS
Time of occurrence
start
MM-DD-YY,HH-MM-SS
Start time
stop
MM-DD-YY,HH-MM-SS
Stop time
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com