12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 381
TL1 Reference
Set Commands
Set Name
The Set Name command applies the specified name to the TSG-3800. You can use
up to 10 characters for the name.
When the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Set Reference
The Set Reference command sets the current input source to the specified input
port.
When the TSG-3800 successfully receives the command and if the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Example Command
SET-EVNT:TSG:ALL:ctag;
Example Response
TSG 02-05-16 14:36:46
M 14 COMPLD
;
Command Syntax
SET-NAME:[tid]::ctag::name;
Valid aid
none
name: up to 10 characters or null
Minimum User Level
3
Example Command
SET-NAME:TSG::ctag::TSG3800;
Example Response
TSG3800 02-05-16 14:45:49
M 15 COMPLD
;
Command Syntax
SET-REF:[tid]:[aid]:ctag;
Valid aid
INPx[-y]
For single-port Input modules x is 1–4 and y is always 1. For
three-port Input modules x is 1-4 and y is 1-3.
Minimum User Level
3
Example Command
SET-REF:TSG:INP3-3:ctag;
Example Response
TSG3800 02-05-16 14:51:32
M 15 COMPLD
;