System Administrator’s Reference
Provisioning Input Reference Signals
340
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Example
Purpose: Prevent previous MTIE data for the primary input from causing a MTIE
fault at the end of the measurement cycle.
Command:
MTIE 1.1 INHIBIT
Display:
TSG->MTIE INP1.1 INHIBIT
«date» «time» «oper» Temporarily Inhibited MTIE Faults for
«input»
TSG->
To prevent previous frequency data from affecting current measurements, type:
FREQUENCY «input» INHIBIT
then press
Enter
where «input» is described in
Table B-3
(default is all inputs)
Example
Purpose: Prevent previous frequency data for the secondary input from causing a
frequency fault at the end of the measurement cycle.
Command:
FREQUENCY INP2.1 INHIBIT
Display:
TSG->FREQUENCY INP2.1 INHIBIT
«date» «time» «oper» Temporarily Inhibited Frequency Faults
for «input»
TSG->