12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 391
TL1 Reference
Retrieve Commands
Retrieve Input Condition
The Retrieve Input Condition command displays the current operating mode and
status of the selected input ports.
If the TSG-3800successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Retrieve Configuration
The Retrieve Configuration command reports configuration (inventory
management) information for the specified module.
Minimum User Level
2
Example Command
RTRV-COND-EQPT:TSG:ALL;
Example Response
TSG 10-05-15 13:17:40
M 1 COMPLD
“CPU:Run,OK”
“ClkA:Lock,OK”
“ClkB:Lock,Ref”
“FGA:Auto,OK”
“FGB:Auto,Ref”
;
Command Syntax
RTRV-COND-INP:[tid]:[aid]:ctag;
Response Format
^^^aid:mode,status<cr><lf>
where Mode is Ref|OK|Mon|Dis
and Status is OK|Alrm|Fail
Valid aid
INP, INPx, INPx[-y], ALL, <null>
Minimum User Level
2
Example Command
RTRV-COND-INP:TSG:INP3;
Example Response
TSG 10-05-15 13:17:40
M 1 COMPLD
“INP3-1:Ref,OK”
“INP3-2:OK,OK”
“INP3-3:Mon,OK”
;
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com