12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 393
TL1 Reference
Retrieve Commands
Retrieve Alarm Data
The Retrieve Alarm Data command reports the error and clear counts for the
specified error and aid.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Retrieve Clock Data
The Retrieve Clock Data command reports the current 1-s and 100-s control values
and tau for the A and B clocks.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Minimum User Level
2
Example Command
RTRV-CONF:TSG:CLKA:ctag;
Example Response
TSG 02-09-10 19:00:19
M 1 COMPLD
“CLKA:ST2RUB,Config Not Available”<cr><lf>
Command Syntax
RTRV-DATA-AIS:[tid]:[aid]:ctag;
RTRV-DATA-BPV:[tid]:[aid]:ctag;
RTRV-DATA-CRC:[tid]:[aid]:ctag;
RTRV-DATA-LOS:[tid]:[aid]:ctag;
RTRV-DATA-OOF:[tid]:[aid]:ctag;
Valid aid
INP, INPx, INPx[-y], ALL, <null>
Minimum User Level
1
Response Format
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^aid:prmtr,ercnt,clcnt<cr><lf>
Example Command
RTRV-DATA-AIS:TSG:INP2:ctag;
Example Response
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^TSG:AIS,1,5
Command Syntax
RTRV-DATA-CLK:[tid]:[aid]:ctag;
Valid aid
CLK, CLKA, CLKB, ALL, <null>
Minimum User Level
2