TSG-3800 User’s Guide 385
TL1 Reference
Set Commands
Set Frequency
The Set Frequency Parameter command sets the frequency stability thresholds for
the specified input. The threshold settings lim1 and lim2 are values in ps/s. The
error mode mod1 and mod2 determine what happens when lim1 and lim2 are
exceeded, respectively. The tmper determines which time period the thresholds and
error conditions apply to. Use aid ALL or <null> to specify all inputs.
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Set Input
The Set Input Parameter command provisions the selected T1/E1 Input module.
Use aid ALL or <null> to specify all inputs.
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
SET-PRMTR-FREQ:[tid]:[aid]:ctag::lim1,mod1,
lim2,mod2, tmper;
Valid aid
INP, INPx, INPx[-y], ALL, <null>
lim1, lim2 = <number>
mod1, mod2 = Fail, Alrm, Rept, Ignr
tmper = 100, 1000, 10000
Minimum User Level
2
Example Command
SET-PRMTR-FREQ:TSG3800:INP1:ctag:175,Alrm,200
,Fail,1000;
Example Response
TSG3800 02-09-11 09:49:07
M 630 COMPLD
;
Command Syntax
SET-PRMTR-INPT:[tid]:[aid]:ctag:mode,zs,crc,
freq,term;
Valid aid
INP, INPx, INPx[-y], ALL, <null>
mode: T1 modules: D4, ESF, CLK
E1 modules: CAS, CCS, CLK
zs = On or Off
crc = On or Off
Freq = 1, 1.544, 2.048, 5, 10
term = 50, 75, 100, 120, 3300
Minimum User Level
2