12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 233
Output Modules
Analog Output Module
Configuring the Analog Output Module
This section describes how to configure the Analog Output module to meet the
requirements of your particular installation.
Setting Jumpers W3 and W5
Use jumpers on W3 and W5 to define the source of the clock signal to be used by
the module. These jumpers also configure the module for compatibility with the
Frame Generator you are using.
Table 7-20
describes the appropriate settings.
Setting the Output Frequency
Jumpers W11-Ch1, W10-Ch2, W9-Ch3, W8-Ch4, W7-Ch5, and W6-Ch6 must be
set to the 1 MHz, 5 MHz, or 10 MHz position. Each channel’s output frequency is
independent of the other channels.
Caution:
To prevent ESD damage to the module, always observe the
precautions described in
Properly Handling the Modules
, on page 61.
Table 7-20. Frame Generator Compatibility Jumper Settings
Frame Generator Clock (MHz)
W3
W5 (MHz)
Clock 1 = 1.544 (default)
Clock 1
1.544
Clock 1 = 2.048
Clock 1
2.048
Clock 2 = 1.544
Clock 2
1.544
Clock 2 = 2.048
Clock 2
2.048
Caution:
To avoid improper operation of the module, do not change
jumpers W1, W2, and W4.