![background image](http://html.mh-extra.com/html/symmetricom/tsg-3800-series/tsg-3800-series_user-manual_1419615380.webp)
12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 379
TL1 Reference
Set Commands
When the TSG-3800 successfully receives the command and if the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Set Date
The Set Date command sets the date stored in the TSG-3800.
When the TSG-3800 successfully receives the command, it returns the COMPLD
message with the new date and time in the header. If the TSG-3800 does not
successfully receive the command, it returns the DENY message.
Set Disable
The Set Disable command disables the specified Clock module, Frame Generator
module, Input module, or input port. The aid TL1_SECU disables the need to use a
valid user name and password to log in to a TL1 connection.
When the TSG-3800 successfully receives the command and if the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
SET-CLK:[tid]:[aid]:ctag;
Valid aid
CLK A, CLK B
Minimum User Level
Example Command
SET-CLK:TSG:CLK A;
Example Response
TSG 02-09-06 11:26:20
M 1 COMPLD
;
Command Syntax
SET-DAT:[tid]::ctag::date^time;
Valid aid
must be null
date^time = YY-MM-DD^HH:MM:SS, where ^ can be a space
or a comma and the time separator can be colons or dashes
Minimum User Level
2
Example Command
SET-DAT::ctag:08-28-02,15:25:00;
Example Response
TSG 02-08-28 15:25:00
M 13 COMPLD
;
Command Syntax
SET-DIS:[tid]:[aid]:ctag;
Valid aid
CLKx, FGx, INPx, INPx[-y], TL1_SECU
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com