Operating the TSG-3800
Default Parameter Values
108
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Restarting the TSG-3800
You can restart the TSG-3800 and reset it to the default settings using the Restart
command. When restarted, the Clock modules cycle through the Acquire and
Locked operating modes again. This command has the same effect as powering
down and re-applying power to the shelf.
To restart the TSG-3800, type:
RESTART
then press
Enter
Default Parameter Values
This section describes the factory default values and the range of selections.
Table
3-6
lists the software default settings and
Table 3-7
lists the hardware default
settings. Both tables have a column for entering your own settings.
Caution:
The
RESTART command causes the processor to execute
the self-test routine. The self-test routine erases measurement history
and clears all disabled or failed modules.
Table 3-6. Default Software Configuration
Setting
Factory Default
Range
User Settings
SOFTWARE PROVISIONS (X-Port Input Module, P/N 23478303-00x-0)
Input AUTORETURN
ON
ON/OFF
Input AUTOSWITCH
ON
ON/OFF
Signal Type
T1
T1/E1/CLOCK
Signal Framing
T1
ESF
ESF/D4
E1
CCS
CCS/CAS
Input Clock Freq
1MHz
1/ 1.544/ 2.048/ 5/ 10 MHz
Zero Suppression ZS
OFF
ON/OFF
CRC
OFF
ON/OFF
SSM
OFF
ON/OFF
Input Termination
3300
3300/ 120/ 100/ 75/ 50
MTIE/FREQ Mask
MCD
PRS/OCN/MCD
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com