System Administrator’s Reference
System Messages
362
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
35
Message,
Event, Ref
Input Module
Selected as
Reference
This event signals that the system has chosen a new
Input module as reference.
37
Equipment,
Event, Alarm
Minor Alarm
Cleared
This event signals that the CPU has turned off the
minor alarm LED and relays
39
Equipment,
Event, Alarm
Major Alarm
Cleared
This event signals that the CPU has turned off the
major alarm LED and relays.
40
Input, Major,
Ref
No Valid
Reference
Found
This event signals that the CPU has determined that
no input should be used as a reference.
41
Input, Event,
Ref
Valid
Reference
Found
This event signals that the CPU has determined that
an input or inputs may be used as a reference.
42
Equipment,
Critical, Intifcfail
Output
Reference
Invalid
This event signals that the CPU has determined that
none of the Clock modules are suitable for use as a
master clock. This typically means that the Clock
modules are in warmup, holdover, or have a problem.
43
Equipment,
Event, Msg
Output
Reference
Valid
This event signals that the CPU has determined that
at least one of the Clock modules are suitable for use
as a master clock.
44
Equipment,
Major, Alarm
Distribution
Output Fault
This event occurs when the output modules signal the
CPU that they are no longer able to produce a
suitable output. Typically means that one or more of
the output signals has a problem.
45
Equipment,
Event, Alarm
Distribution
Output Fault
Cleared
This event signals that the output modules have
restored normal output signals.
46
Equipment,
Minor, Alarm
Distribution
Input Fault
This event signals that the output modules are not
receiving timing information from the frame generator.
This typically occurs when there is a problem with the
frame generator.
47
Equipment,
Event, Alarm
Distribution
Input Fault
Cleared
This event signals that the output modules timing
information from the frame generator has been
restored.
48
Equipment,
Event, Msg
Configuration
Loaded
This event occurs on bootup and signals that the user
default configuration has been restored from
non-volatile memory.
49
Equipment,
Event, Msg
Default
Configuration
Loaded
This event signals that the unit has reloaded the
factory default configuration from eprom. This event
will only occur on bootup.
Table B-5. Event Listing (Continued)
Event
No.
Type
Description
Comment