System Administrator’s Reference
Overview of the TSG-3800 Security System
310
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
7. Type your password and press
Enter
. If the command prompt appears, then
communications are established.
8. If you have forgotten your user name and password, contact your system
administrator or call Symmetricom Global Services for assistance.
9. Type
bye
and press
Enter
to log off the system after all tasks have been
performed.
Overview of the TSG-3800 Security System
The software in the CPU module contains a hierarchy of user levels that permit an
increasing level of access to system parameters. This allows Administrator-level
users to add users that can, for example, view but not change system parameters;
users at other levels can view and change system parameters.
For a first-time installation, the default login is at the Administrator level. When
adding users, first add an Administrator-level user and password to avoid a service
call. Users at the Administrator level set up other users, their passwords, and their
level of security.
There are four user privilege levels: Administrator or System (Level 4), Supervisor
(Level 3), Technician (Level 2), and User (Level 1) The Administrator level allows
the user to modify the user list. and to execute all commands. These include
commands that affect system performance, for instance, clock operating mode. The
Supervisor level allows execution of all commands except for saving the user
configuration. The Technician level allows the operator to perform basic
configuration commands. The User level only allows execution of non-critical
commands.
Table B-2
summarizes each security level, ID number, and the
privileges available at each level.
If you do not define a user list, the TSG-3800 accepts all commands.
Table B-2. User Access (Security) Levels
Level
ID
Description
User
1
User-level users can:
View information about the current configuration and operation
Change communication settings such as line termination and echo
Changes made by users at this level remain in effect only until the user
logs out.
Technician
2
Technician-level users (CRAFT persons) can:
Perform level 1 functions
Read or set all installation functions