Installing the TSG-3800
Making Electrical Connections
58
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
7. Insert the fuses, see
Figure 2-10
. This powers up the shelf
8. Verify that all modules are receiving power; their POWER indicators are green.
Check that the RUN indicator on the CPU module is green.
9. To ensure that
both
power inputs are valid, verify that the amber POWER
indicator on the front of the CPU module is off; see
Figure 6-1
for its location. If
the POWER indicator is on, check the power inputs. This indicator lights if one of
the power inputs is not present or malfunctioning.
Figure 2-9.
Power Connections
Figure 2-10. Fuse and Power Connection Details
Caution:
For continued fire protection, replace fuse with specified
type and rating. Fuse: GMT-5 (5A @ 60vDC). This unit must be
grounded. Refer all servicing to qualified personnel.