12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 333
System Administrator’s Reference
Provisioning Input Reference Signals
Display: TSG->INPUT 4.1 AIS ZERO
«date» «time» «oper» zeroed AIS error counter for «input»
TSG->
Viewing Phase Measurements
The TSG-3800 measures the phase between each input and each clock. You can
display:
The most recent phase measurement for all inputs
Up to the last one hundred 1-second interval phase readings between the clocks
and a specified input
Up to the last one thousand 100-second average phase readings (27 hours)
between the clocks and a specified input
The readings are displayed in nanoseconds (chronological).
To view the most recent phase measurements for all inputs, type:
PHASE
then press
Enter
A typical response from the TSG-3800 is:
->PHASE
The Current Time is 20JUN2004 08:32:01.122
To display the last
n
phase readings on a specified input, type:
PHASE «input» [T1|T100] «n»
then press
Enter
where «input» is described in
Table B-3
(default is the
selected reference)
T1 is 1-s averages (default) T100 is 100-s averages
«n» is 1 to 100 for 1-s averages and 1 to 1000 for 100-s
averages.
The Phase (1 sec) for Inp1.1 is
0
0
The Phase (1 sec) for Inp1.2 is
0
0
The Phase (1 sec) for Inp1.3 is
0
0
The Phase (1 sec) for Inp2.1 is
1
0
The Phase (1 sec) for Inp3.1 is
0
-1
The Phase (1 sec) for Inp3.2 is
0
0
The Phase (1 sec) for Inp3.3 is
-12
0
The Phase (1 sec) for Inp4.1 is
0
0
->
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com