12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 361
System Administrator’s Reference
System Messages
25
Input, Minor,
OOF
OOF Input
Fault
This event signals that the given Input module has
detected an OOF (out of frame) and is reporting that
the input error counter has incremented past the error
limit.
NOTE
: This event only occurs when the alarm
mode is REPORT or ALARM.
26
Input, Minor,
BPV
BPV Input
Fault
This event signals that the given Input module has
detected an BPV (bipolar violation) and is reporting
that the input error counter has incremented past the
error limit.
NOTE:
This event only occurs when the
alarm mode is REPORT or ALARM.
27
Input, Minor,
LOS
LOS Input
Fault
This event signals that the given Input module has
detected an LOS (loss of signal) and is reporting that
the input error counter has incremented past the error
limit.
NOTE:
This event only occurs when the alarm
mode is REPORT or ALARM.
28
Input, Minor,
AIS
AIS Input
Fault
This event signals that the given Input module has
detected an AIS (alarm indication signal) and is
reporting that the input error counter has incremented
past the error limit.
NOTE:
This event only occurs
when the alarm mode is REPORT or ALARM.
29
Input, Event,
OOF
Input
Restored
From OOF
Fault
This event signals that the given Input module is not
indicating OOF and the clear counter has
incremented past the clear limit.
30
Input, Event,
AIS
Input
Restored
From AIS
Fault
This event signals that the given Input module is not
indicating AIS and the clear counter has incremented
past the clear limit.
31
Input, Event,
LOS
Input
Restored
From LOS
Fault
This event signals that the given Input module is not
indicating LOS and the clear counter has incremented
past the clear limit.
32
Input, Event,
BPV
Input
Restored
From BPV
Fault
This event signals that the given Input module is not
indicating BPV and the clear counter has incremented
past the clear limit.
33
Equipment,
Event,
Restored
Module
Restored
Event
This event signals that the given module has been
cleared of all fail conditions and is now operating
properly.
34
Equipment,
Major, Intifcfail
Module Failed
Event
This event signals that the given module has failed
and gives the hex value for the cause if possible.
Table B-5. Event Listing (Continued)
Event
No.
Type
Description
Comment
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com