MTIE Command
Use this command to display and provision all Maximum Time Interval Error (MTIE)
parameters.
Name Command
Use this command to display and name the TSG-3800. The name is used as the
[tid] in TL1 communications.
Level 0
Not applicable
Level 1
MTIE «input» [T100|T1000|T10000] [CURRENT|[number]]
MTIE «input» [[startdate] [starttime]] [[stopdate]
[stoptime]]
MTIE «input» MODE
where:
T100/T1000/T10000 is the time scale (window size)
startdate/stopdate is in the format mm/dd/yyyy
starttime/stoptime is in the format hh:mm
Current displays the current calculation
number displays 1 to 50 (default 1) MTIE calculations
Mode displays the alarm mode for the selected channel
Level 2
MTIE INHIBIT
where:
Inhibit disables MTIE alarms
Level 3
MTIE «input» [T100|T1000|T10000] LIMIT [L1 [1-100000]|L2
[1-100000]
MTIE «input» MODE [L1 [alarm mode]|L2 [alarm mode]]
where:
Limit displays/sets the L1/L2 alarm threshold limits
Mode displays/sets the L1/L2 alarm modes
Level 4
Same as Level 3 operation
Remarks
None
Related
TDEV
Restrictions
None
Level 0
Not applicable
Level 1
NAME
Level 2
Same as level 1 operation
Level 3
Same as level 1 operation