12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 399
TL1 Reference
Retrieve Commands
Retrieve MTIE
The Retrieve MTIE command reports the true MTIE data from the specified port.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
RTRV-PD-MTIE:[tid]:[aid]:ctag[::start][:stop];
Valid aid
INPx[-y]
Minimum User Level
1
Response Format
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^”aid:ocrdat,ocrtim,MTIE”<cr><lf>
^^^tmper,monval[<cr><lf>
^^^tmper,monval...]”
;
where:
ocrdat and ocrtime are the actual date and time the data
were collected
MTIE describes the data that follows
tmper is the data measurement time period in seconds.
Maximum values are 0.05, 0.1, 1.0, 10.0, 100.0, 1000.0
and 10000.0. Only values available in the interval between
the start and stop time are reported.
monval is the data value for the tmper in nanoseconds
Example Command
RTRV-PD-MTIE:TSG:INP2-3:ctag;
Example Response
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^
;
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com