12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 343
System Administrator’s Reference
Command Reference
Communication Command
This command allows you to display and modify the parameters that affect the
EIA-232 ports on the TSG-3800.
Table B-4. Time Constant Values for Each Type of Clock Module
Type
Starting TC
Minimum TC
Maximum TC
Pull-in Range
Stratum 2 Rb
100
500
10000
+5.76 x 10E
–8
Stratum 2.0 DDS
50
100
5000
+5.76 x 10E
–8
Stratum 2.0
50
100
5000
+5.76 x 10E
–8
Stratum 2.1 DDS
50
100
5000
+5.76 x 10E
–8
Stratum 2.1
50
100
5000
+5.76 x 10E
–8
Stratum 3E
20
20
1000
+1.6 x 10E
–5
Level 0
Not applicable
Level 1
COMM [A|B] [BAUD|ECHO|EOL|HAND|MODE|TIMEOUT]
Displays the values for each parameter
Level 2
COMM [A|B] BAUD [300|1200|2400|4800|9600|19200]
COMM [A|B] ECHO [OFF|ON]
COMM [A|B] EOL [LF|CR|CRLF]
COMM [A|B] HANDSHAKE [OFF|HARDWARE|SOFTWARE]
COMM [A|B|TELNET|BINARY] TIMEOUT [5 - 43200]
All values set at this level revert to default/stored values at logoff.
where:
Baud is the baud rate of the port (default = 9600)
Echo is used for full/half duplex operation (default = On)
EOL sets the End of Line termination (default = CRLF)
Handshake determines the method of connection (default = Off)
Timeout sets the length of inactive time before automatically logging off the
user (default = 300)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com