TL1 Reference
Retrieve Commands
390
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Retrieve Current Alarms
The Retrieve Current Alarms command reports all active alarms from the TSG-3800
or from the selected module. There is no report message for modules or inputs that
are not in alarm. The condscr contains the event identification number as described
in
Table C-6
.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message followed by the alarm message report. If it does not successfully receive
the command, it returns the DENY message.
Retrieve Equipment Condition
The Retrieve Equipment Condition command reports the mode status of the
TSG-3800 or of the selected module or input.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG0-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
RTRV-ALMS:[tid]:[aid]:ctag;
Response Format
^^^“aid:ntfcncde,condtype,srveff,\“condscr\””
Valid aid
CPU, INPx[-y], CLKA, CLKB, FGA, FGB
Minimum User Level
1
Example Command
RTRV-ALMS:TSG:CLKA:ctag;
Example Response
TSG 02-09-25 03:01:36
M 1 COMPLD”
“A ,00,00,00,00,00”
or
TSG 02-09-15 09:57:25
M 1 COMPLD”
“*C,03,18,”
;
Command Syntax
RTRV-COND-EQPT:[tid]:[aid]:ctag;
Response Format
^^^aid:mode,status<cr><lf>
where Mode for:
CPU is Run|Halt
Clocks is Warm|Hold|ACQ|Lock
FGs is Man|Auto|Bypass
and Status for:
CPU is OK|Pwrfail
Clocks and FGS is Ref|OK|Fail|Dis
Valid aid
CPU, CLK, CLKA, CLKB, FG, FGA, FGB, ALL,
<null>
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com