12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 107
Operating the TSG-3800
System Commands
CPU
Power A: On Power B: On
Alarms Minor
->
Checking the Instrument Configuration
You can display a listing of all instrument settings stored in memory (fault limits,
baud rates, and so forth) using the Setup command. Where the operator has not set
a limit, the default value is shown. The operator can also reset the limits to factory
default values or user defined default values.
To access the configuration data, type:
SETUP [start input] [ending input]
then press
Enter
A typical display is:
->SETUP INP1.1
Input: Mode - Best AutoSwitch - On AutoReturn - On
Clock: AutoReturn - On
Inp1.1
Provisioned SSM: STU SSM Mode: Auto SSM Alarm Mode: Report E1 SSM
Bit#: 4
Priority: 1
->
Type
Mode/Status
Stability
Tau
%Range
Clk A
Stratum 2
Rubidium
Locked/Ref
1.68E-15
2500.0
0
49%
Clk B
Stratum 2 DDS
Locked/OK
1.06E-13
1500.0
0
49%
Type
Mode/Status
Output
SSM
Bypass
FG A
T1/E1 (SSM)
Ref/Auto
ST Unknown
No
FG B
T1/E1 (SSM)
OK/Auto
ST Unknown
No
Limit 1
Limit 2
Limit 1
Limit 2
Freq(100):
8000-Fail
4000-Alarm
MTIE(100):
432-Fail
324-Alarm
Freq(1000):
800-Fail
400-Alarm
MTIE(1000):
864-Fail
648-Alarm
Freq(10000):
80-Fail
40-Alarm
MTIE(10000:
1728-Fail 1296-Alarm
AIS
BPV
CRC
LOS
OOF
Set: 10
Set: 10
Set: 10
Set: 10
Set: 10
Clr: 2
Clr: 2
Clr: 2
Clr: 2
Clr: 2
Mode: Fail
Mode: Alarm
Mode: Fail
Mode: Fail
Mode: Alarm