Operating the TSG-3800
Provisioning the Clock Modules
102
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Example
Purpose: Disable Clock A before removing it.
Command:
DISABLE CLK A
Display:
->DISABLE CLK A
«date» «time» «oper» Disabled Clk A
«date» «time» Clk B selected for output, Stratum 2.1
+>
You can only disable one module at a time, and you cannot disable either a Clock or
Frame Generator module if the other Frame Generator and Clock pair are not
present. If either situation exists when attempting to disable, the following message
appears:
->DISABLE CLK B
CLK/FG is Already Disabled in Other Pair: Can’t Disable
->
You must manually enable any disabled module. After enabling a disabled Clock,
the Clock enters the Acquire mode.
To enable a module:
ENABLE CLK|FG A|B
then press
Enter
Example
Purpose: Enable Clock A.
Command:
ENABLE CLK A
Display:
->ENABLE CLK A
«date» «time» «oper» Enabled Clk A
+>
Note:
Removing and re-installing modules, or powering down the
shelf also enables a module.
Note:
Enabling a module clears all alarms associated with the
enabled module. If the fault still exists, the alarm returns.