12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 367
System Administrator’s Reference
System Messages
105
Output, Event,
Msg
Restart
Warning
Message
This event counts down to the system restarting.
106
Message,
Event, Msg
Restart
Message
This event occurs when the Operator enters the
restart command.
107
Output, Event,
Msg
Automatic
Logoff
Warning
Message
This event occurs before the software automatically
logs the user out on this port. This is only displayed on
the port that the operator will be logged out on.
108
Equipment,
Major, Ref
External
Reference
LOS Failed
This event occurs when the external reference
module signals an LOS. (3860 only)
109
Equipment,
Event, Ref
External
Reference
LOS
Restored
This event occurs when the external reference
module recovers from an LOS. (3860 only)
110
Equipment,
Major, Bus
Module Bus
Failed
This event occurs when a module fails its bus test.
111
Equipment,
Event,
Restored
Module Bus
Restored
This event occurs when a module recovers from
failing its bus test.
112
Equipment,
Event, Intifcfail
Not Enough
Memory
This event occurs when the CPU can not allocate
enough memory for a given task.
113
Message,
Event, Msg
Binary Server
Session
Failed
This event occurs when a binary session fails and
disconnects.
114
Equipment,
Event, Msg
Binary Server
Failed
This event occurs when the binary server fails and
shuts down.
115
Equipment,
Major, Alarm
Clock Failed
Due To
Stability
Problem
This event occurs when the clock output becomes
unstable.
116
Equipment,
Event,
Restored
Clock Stability
Restored
This event occurs when the clock output stability
recovers.
117
Message,
Event, CRC
Began CRC
This event occurs when the input port signals a CRC.
118
Message,
Event, CRC
Ended CRC
This event occurs when the input port signals that the
CRC error condition has ended.
Table B-5. Event Listing (Continued)
Event
No.
Type
Description
Comment