Operating the TSG-3800
System Commands
106
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Checking Instrument Status
You can display the instrument status using the Status command. Included in the
display is information on major or minor alarms, input error status for each channel,
and current oscillator operating mode.
Frequency and MTIE use the following abbreviations: ‘Ok’, ‘Mon’, ‘Inh’, ‘Alm’, and
‘Flt’. ‘Ok’ signifies the input signal is operating within alarm limits. ‘Mon’ indicates
Input is O.K. but is set to Monitor Only Mode and will not be used as a reference.
‘Inh’ is displayed when the input alarm checking is inhibited. ‘Alm’ is displayed when
the input is in alarm but not faulted. ‘Flt’ is displayed when the input is faulted.
AIS, BPV, CRC, LOS, and OOF use the following abbreviations: ‘E’, ‘A’, and ‘F’. ‘E’
is displayed when the input signal is in episode and not faulted or alarmed. ‘A’ is
displayed when the input signal is in alarm but not faulted. ‘F’ is displayed when the
input signal is faulted.
To access the status data, type:
STATUS
then press
Enter
A typical display is:
->STATUS
The Current Time is 29AUG2004 09:15:40.352
A B C L O
MTIE
FREQ
I P R O O
Port
Type
Status
Phase
100/1K /10K
100/1K /10K
S V C S F
SSM
1.1
3Port/E1
Ref
7
Ok /Ok /Ok
Ok /Ok /Ok
/ / / /
PRS
1.2
3Port/E1
Mon
15
Ok /Ok /Ok
Ok /Ok /Ok
/ / / /
ST2
1.3
3Port/E1
Mon
-55
Ok /Ok /Ok
Ok /Ok /Ok
/ / / /
STU
2.1
DS1
Ok
0
Ok /Ok /Ok
Ok /Ok /Ok
/ / / /
STU
3.1
3Port/T1
Ok
9
Ok /Ok /Ok
Ok /Ok /Ok
/ / / /
PRS
3.2
3Port/T1
Mon
-146
Ok /Ok /Ok
Ok /Ok /Ok
/ / / /
ST2
3.3
3Port/T1
Dis
0
Ok /Ok /Ok
Ok /Ok /Ok
/ / / /
STU
4.1
Clock
Flt
-1232442
Ok /Flt
Flt /Flt /Ok
/ / / /
STU