12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 389
TL1 Reference
Retrieve Commands
Retrieve Commands
Each Retrieve command submitted by the user causes the TSG-3800 to respond
with the Complied message and a response message that contains the requested
data.
Valid <tid> code: the assigned tid (see SET-TID; the default TID is TSG) or null. If
null, the TSG-3800 requires the <aid>.
Valid <aid> code:
Null (no characters). If null, the TSG-3800 requires the <tid>
ID00000
Retrieve Alarms
The Retrieve Alarms command reports all active alarms from the TSG-3800 or from
the selected module. The text_block contains the highest-severity alarm level of all
alarms in the list, and contains the most recent alarms.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If it does not successfully receive the command, it returns the DENY
message.
Command Syntax
RTRV-ALMS:[tid]:[aid]:ctag;
Response Format
^^^“aid:ntfcncde,condtype,srveff,\“condscr\””
<cr><lf>
Valid aid
CPU, INPx[-y], CLKA, CLKB, FGA, FGB
Minimum User Level
1
Example Command
RTRV-ALMS:TSG:CLKA:ctag;
Example Response
TSG 02-09-25 03:01:36
M 1 COMPLD”
“A ,00,00,00,00,00”
or
TSG 02-09-15 09:57:25
M 1 COMPLD”
“*C,03,18,”
;
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com