12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 409
TL1 Reference
Retrieve Commands
Retrieve Priority Parameter
The Retrieve Priority Parameter command reports the priority level for the specified
input port.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Response Format
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^aid:MTIE,lim1,mod1,lim2,mod2,tmper<cr><lf>
where:
lim1 and lim2 are the threshold values
mod1 and mod2 are the alarm mode settings
[Fail|Alarm|Rept| Ignr]
tmper is 100|1000|10000
Example Command
RTRV-PRMTR-MTIE:TSG::ctag;
Example Response
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^TSG:
;
Command Syntax
RTRV-PRMTR-PRI:[tid]:[aid]:ctag;
Valid aid
INP, INPx, INPx[-y], ALL, <null>
Minimum User Level
2
Response Format
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^aid:level<cr><lf>
where:
level is 1 (highest) through 4 (lowest), Mon (for Monitor
mode) or Dis (for disabled)
Example Command
RTRV-PRMTR-PRI:TSG::ctag;
Example Response
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^INP2:Mon
;
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com