TL1 Reference
Retrieve Commands
406
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Retrieve Alarm Parameters
The Retrieve Alarm Parameters command reports the error and clear counts as well
as the current mode for the specified error and input port.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Retrieve Clock Parameters
The Retrieve Clock Parameters command reports the settings of the specified Clock
module.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
RTRV-PRMTR-AIS:[tid]:[aid]:ctag;
RTRV-PRMTR-BPV:[tid]:[aid]:ctag;
RTRV-PRMTR-CRC:[tid]:[aid]:ctag;
RTRV-PRMTR-LOS:[tid]:[aid]:ctag;
RTRV-PRMTR-OOF:[tid]:[aid]:ctag;
Valid aid
INP, INPx, INPx[-y], ALL, <null>
Minimum User Level
2
Response Format
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^aid:prmtr,ercnt,clcnt,mode<cr><lf>
where:
ercnt is the error count
clrcnt is the clear count
mode is Fail|Alrm|Rept|Ignr
Example Command
RTRV-PRMTR-AIS:TSG:INP2:ctag;
Example Response
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^TSG:AIS,1,5 ALRM
Command Syntax
RTRV-PRMTR-CLK:[tid]:[aid]:ctag;
Valid aid
CLK, CLKA, CLKB, ALL, <null>
Minimum User Level
2