12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 363
System Administrator’s Reference
System Messages
50
Message,
Event, Oper
User Set
Reference
Module
This event signals that an operator has set the
reference module that the unit is to use. Unless
autoswitch and/or autoreturn is off, the unit will return
to the most suitable reference.
51
Message,
Event, Oper
User Set
Loop Mode
This event signifies that the operator has set the
Clock modules operating mode.
52
Message,
Event, Oper
User Set
Alarm
Parameter
This event signals that the operator has changed one
of the Input modules alarm error or clear limits.
53
Message,
Event, Oper
User Zeroed
Alarm
Parameter
This event signals that the operator has zeroed,
cleared, the specified error counter for the given Input
module.
54
Message,
Event, Oper
User Set
Alarm Mode
This event signals that the operator has set the alarm
mode for the given Input module.
55
Equipment,
Major, Intifcfail
System Bus
Failed
This event signals that the CPU has determined that it
is unable to properly read from the bus. This typically
means that a module is disrupting the data on the bus.
56
Equipment,
Event,
Restored
System Bus
Restored
This event signals that the CPU has regained use of
the bus and is reading valid data from the modules.
57
Equipment,
Minor, Intifcfail
One PPS
Failed
This event signals that the CPU has failed the 1 PPS
signal from a Clock module. This typically occurs
when the 1 PPS signal is off frequency or is not at the
proper level.
58
Equipment,
Event,
Restored
One PPS
Restored
This event signals that the CPU has regained the 1
PPS signal from a Clock module.
59
Message,
Event, Oper
User Set Osc
Time
Constant
This event signals that the operator has set the time
constant (tc) for the given Clock module.
60
Message,
Event, Oper
Module
Disabled
This event signals that the operator has disabled a
clock or Frame Generator module. This module is not
available for use as a master and will not provide
timing for the unit.
61
Message,
Event, Oper
Module
Enabled
This event signals that the operator has enabled a
clock or Frame Generator module. This event also
occurs when the operator enables a failed module.
This module now begins normal operation.
62
Input, Minor,
Mtie
Mtie Limit 1
Exceeded
This event occurs when the given inputs Mtie has
exceeded limit 1.
Table B-5. Event Listing (Continued)
Event
No.
Type
Description
Comment