background image

Light Curtain 

SF2B

 Series

Sub Sensor Exclusive for Series Connection

SF2B-□SL

Instruction Manual

MJE-SF2BSL No.0053-18V

2016.1

panasonic.net/id/pidsx/global

Содержание SF2B Series

Страница 1: ...Light Curtain SF2B Series Sub Sensor Exclusive for Series Connection SF2B SL Instruction Manual MJE SF2BSL No 0053 18V 2016 1 panasonic net id pidsx global...

Страница 2: ...Panasonic Industrial Devices SUNX Co Ltd 2016 2 MEMO...

Страница 3: ...light curtains as well as safety systems and standards who are responsible for the introduction of this device who design the system using this device who install and connect this device who manage a...

Страница 4: ...Part Description 9 2 2 Mounting 11 2 2 1 Mounting of the Mounting Bracket 11 2 2 2 Mounting of the Connector for Series Connection Optional 15 2 3 Wiring 17 2 4 Adjustment 19 Chapter 3 Specifications...

Страница 5: ...regional security committees Occupational Safety and Health Administration OSHA the European Standardization Committee etc Contact the relative organization s for details In case of installing this d...

Страница 6: ...ng part of this device is directly exposed to light from high frequency fluorescent lamp inverter type or rapid starter fluorescent lamp Installation Always keep the correctly calculated safety distan...

Страница 7: ...nowledge After maintenance or adjustment and before starting operation test this device following the set procedure For details refer to Instruction Manual for SF2B Series Clean this device with a cle...

Страница 8: ...ng the bottom cap cable SF2B CB05 A optional this device does not conform to OSHA Reference The conformity to JIS OSHA and ANSI for this device has been evaluated by ourselves The CULUS Listing Mark i...

Страница 9: ...m channels are blocked light Besides the receiver displays its status on the display section Beam channel The light emitting elements of the emitter and the light receiving elements of the receiver ar...

Страница 10: ...e control output OSSD 1 2 the operation indicator is marked as OSSD on the device 2 The threshold where the control output OSSD 1 2 changes from OFF to ON is applied as 100 incident beam intensity 3 T...

Страница 11: ...1 optional is used Configuration The standard mounting bracket MS SF2B 1 optional configures as follows 1 Fix the standard mounting bracket with two hexagon socket head bolts M3 length 5mm The tighte...

Страница 12: ...e mounting bracket on to the mounting surface with two hexagon socket head bolts M5 please arrange separately temporarily 5 Adjust the height of the emitter and the receiver to level with the elongate...

Страница 13: ...follows 1 Hook the C part into the groove on the side of the body and press it Note that the position to fit the C part onto the main body differs from the surface where the intermediate mounting bra...

Страница 14: ...Devices SUNX Co Ltd 2016 14 2 Insert the D part or E part into the C part in the step 1 condition 3 Mount the D part or E part on to the mounting surface with the two hexagon socket head bolts M5 plea...

Страница 15: ...SF2B CSL into the connector of the main sensor SF2B and the sub sensor this device When inserting the connector fit the cable into the groove of the main sensor SF2B and the sub sensor this device 3...

Страница 16: ...ection 1 For dismantling the cable for series connection follow the above procedure of Constructing method for the series connection in reverse The cable for series connection SF2B CSL cannot be exten...

Страница 17: ...od depends on the type of bottom cap cable Refer to Instruction Manual for SF2B Series for the details of wiring When SF2B H and SF2B A are combined in series connection double the number of the beam...

Страница 18: ...incorporated in the main sensor such as SF2B H8 or SF2B A4 it cannot be connected in series The connector for series connection is not incorporated in the sub sensors such as SF2B H8SL or SF2B A4SL In...

Страница 19: ...in light blocked status the control output OSSD 1 2 turns OFF Reference The emitter receiver indicators indicate the output status The following figure shows the status of the indicators with Sub Sens...

Страница 20: ...Panasonic Industrial Devices SUNX Co Ltd 2016 20 Beam synchronization using 4 core cable When sufficient light is received...

Страница 21: ...vices SUNX Co Ltd 2016 21 Chapter 3 Specifications Dimensions 3 1 Specifications Model Example SF2B H56SL Beam pitch 20mm Number of beam channels 56 channels Model wise specifications Min sensing obje...

Страница 22: ...Panasonic Industrial Devices SUNX Co Ltd 2016 22 Min sensing object 47mm 40mm pitch type...

Страница 23: ...r of beam channels 36 beam channels 44 beam channels x 2 124 beam channels 3 The intermediate supporting bracket MS SF2B 2 is enclosed with the following devices The quantity of the enclosed bracket d...

Страница 24: ...Panasonic Industrial Devices SUNX Co Ltd 2016 24 3 2 Dimensions 3 2 1 Rear Mounting with Standard Mounting Bracket MS SF2B 1...

Страница 25: ...Panasonic Industrial Devices SUNX Co Ltd 2016 25 3 2 2 Side Mounting with Standard Mounting Bracket MS SF2B 1...

Страница 26: ...ng Center EU Representative s Address Winsbergring 15 22525 Hamburg Germany Product Active Opto electronic Protective Device Light Curtain Model Name SF2B Series Trade Name Panasonic Application of Co...

Страница 27: ...irst edition June 30 2006 Second edition August 31 2007 Third edition October 20 2008 Forth edition October 1 2009 Fifth edition December 20 2010 Sixth edition January 30 2012 Seventh edition January...

Страница 28: ...Panasonic Industrial Devices SUNX Co Ltd 2016 28 MEMO...

Страница 29: ...R ANY INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND GENERAL TERMS AND CONDITIONS 4 OR ANY DAMAGES RESULTING FROM LOSS OF USE BUSINESS INTERRUPTION LOSS OF INFORMATION LOSS OR INACCU...

Страница 30: ...ama cho Kasugai shi Aichi 486 0901 Japan Telephone 81 568 33 7861 Facsimile 81 568 33 8591 panasonic net id pidsx global For sales network please visit our website Panasonic Industrial Devices SUNX Co...