Output Modules
AMI 10-Output Module
220
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Set these three switches for your application. Remember the settings apply to all 10
outputs of the AMI Output module, which means that the same length and type of
cable must be used on all outputs for the pulse shapes to be correct. If the cable
length is not known, change the switches while monitoring the wave shape until a
suitable wave shape is obtained. This may also be a useful method for setting the
switches when different types of cables are used, see
Table 7-9
.
Setting Jumper W4
Installing the AMI 10-Output Module
The AMI 10-Output modules are designed to operate in pairs. Insert one module in
the primary distribution slot; insert the other in the corresponding secondary
distribution slot.
Table 7-5
lists the primary and secondary distribution slots in the
TSG-3800 series.
Table 7-9. T1 Line Length Selections
LEN2
LEN1
LEN0
Option Selected
ON
OFF
OFF
0–133 feet (0–40 m)
OFF
ON
ON
133–266 feet (40–80 m)
OFF
ON
OFF
266–399 feet (80–120 m)
OFF
OFF
ON
399–533 feet (120–160 m)
OFF
OFF
OFF
533–655 feet (160–197 m)
Caution:
Jumper W4 is for factory use only. For proper module
operation, jumpers
must
always be installed between pins 4 and 6,
and between 3 and 5.
Table 7-10. Primary and Secondary Distribution Slots
Model
Primary Distribution Slots
Secondary Distribution Slots
3800/3800E
19-inch Shelves
18, 20
19,21
3800 23-inch
Shelf
18, 20, 22
19, 21, 23
3800X/3800EX
19-inch Shelves
4, 6, 8, 10, 12, 14, 16, 18, 20
5, 7, 9, 11, 13, 15, 17, 19, 21
3800X 23-inch
Shelf
4, 6, 8, 10, 12, 14, 16, 18, 20,
22, 24
5, 7, 9, 11, 13, 15, 17, 19, 21,
23, 25