Specifications
The functional specifications of the ESF/D4 10-Output module are listed in
Table
7-12
.
Configuring the ESF/D4 10-Output Module
This section describes how to configure the ESF/D4 10-Output module to meet the
requirements of your particular installation.
Table 7-12. ESF/D4 10-Output Module Specifications
Signal Characteristic
Specification
Signal
DS1, D4 Framing, All ONEs Data
Waveshape
Rise Time
Pulse Width
Pulse Interval
Duty Cycle
Per ANSI T1.102-1987
< 100 ns
324 ns, nominal
648 ns, nominal
50%
Amplitude
3
±
0.6 V, peak-to-peak
Overshoot
≤
10%
ο
f peak-to-base amplitude
Jitter
< 0.03 UI
Long-term Frequency Error
Exceeds MTIE criteria defined in ANSI T1.101-1987
Clock Performance
Meets SONET requirements per ANSI T1.105-1988
Drive Capability
0 to 655 feet (197 m)
Termination Impedance
100 to 120
Ω
±
5%
Number of outputs
10
Caution:
To prevent ESD damage to the module, always observe the
precautions described in
Properly Handling the Modules
, on page 61.