12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 395
TL1 Reference
Retrieve Commands
Retrieve Phase Data
The Retrieve Phase Data command reports the current 1 and 100 second average
phase readings for the specified input vs. the A and B clocks. The phase values are
in nanoseconds. If you specify more than one input (aid = All or <null>), the data for
each input port is on a separate line.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Retrieve SQL Data
The Retrieve SQL Data command reports the current Sync Quality Level (SQL) for
the specified inputs. This value comes from the SSM, if available; if not, then it
comes from the provisioned value. See
Set SQL
, on page 387, for information on
the SQL definitions. If you specify more than one input (aid = All or <null>), the data
for each input port is on a separate line.
Minimum User Level
1
Response Format
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^”aid:MTIE,m100,m1000,m10000)”<cr><lf>
Example Command
RTRV-DATA-MTIE:TSG:INP3-3:ctag;
Example Response
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^INP3-3:MTIE,158,204,212
Command Syntax
RTRV-DATA-PHA:[tid]:[aid]:ctag;
Valid aid
INP, INPx, INPx[-y], ALL, <null>
Minimum User Level
1
Response Format
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^”aid:PHA,(a1),(b1),(a100),(b100)”<cr><lf>
Example Command
RTRV-DATA-PHA:TSG:INP1:ctag;
Example Response
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^INP1:PHA,0,0,0,0