System Administrator’s Reference
System Messages
370
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
145
Input, Event,
Msg
Input Port 3
Sigma Fault
Cleared
This event signals that the input port phase error
change is under the 3 sigma threshold for that input.
The 3 sigma limit is calculated on the read phase and
is used to determine possible noise bursts.
146
Input, Minor,
Oper
User
Changed FG
Output SSM
This event signals that the user has manually entered
an output SSM for the given frame generator.
147
Equipment,
Major, Clear,
Msg
Unit Entered
Bypass Mode
This event signals that the CPU has determined that
none of the Clock modules are suitable for use with
it’s peer frame generator. This typically means that the
Clock modules are in warmup, do not exist, or have a
fault.
148
Equipment,
Major, Clear,
Msg
Unit Exit
Bypass Mode
This events indicates that the unit has entered normal
operation and is no longer in Bypass mode.
149
Input, None,
Clear, Msg
Input module
has received
an
Unrecognized
SSM
This events indicates that an input has received a
SSM that is not defined in the units SSM(SQL) table.
150
Input, Minor,
Clear, LMHO
Input Failed
due to LMHO
against Clock
A
This events indicates that an input is unable to make
stable phase measurements on a input signal versus
clock A.
151
Input, Minor,
Clear, LMHO
Input Cleared
LMHO
against Clock
A
This events indicates that an input cleared the LHMO
fault versus clock A.
152
Input, Minor,
Clear, LMHO
Input Failed
due to LMHO
against Clock
B
This events indicates that an input is unable to make
stable phase measurements on a input signal versus
clock B.
153
Input, Minor,
Clear, LMHO
Input Cleared
LMHO
against Clock
B
This events indicates that an input cleared the LHMO
fault versus clock B.
154
Input, Minor,
Clear, Alarm
Input Port
Fault
This events indicates that an input port is faulted.
155
Input, Minor,
Clear, Alarm
Input Port
Fault Cleared
This events indicates that an input has cleared the
port fault.
Table B-5. Event Listing (Continued)