System Administrator’s Reference
Provisioning Input Reference Signals
338
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Example
Purpose: Display the last three 100-second frequency measurements for the INP2.1
input.
Command:
FREQUENCY 2.1 T100 3
Display:
TSG->FREQUENCY 2.1 T100 3
«date» «time» The Freq Data (100 sec) for Inp2.1 was 34
«date» «time» The Freq Data (100 sec) for Inp2.1 was 0
«date» «time» The Freq Data (100 sec) for Inp2.1 was 15
TSG->
Displaying Frequency Fault Modes
To display the current Frequency fault mode, type:
FREQUENCY {input} MODE
then press
Enter
where «input» is described in
Table B-3
(default is all inputs)
A typical response from the TSG-3800 is:
TSG->FREQUENCY 3.1 MODE
The Freq Limit 1 Alarm Mode for Inp3.1 is Alarm
The Freq Limit 2 Alarm Mode for Inp3.1 is Ignore
TSG->
Displaying Frequency Limits
To display the current frequency fault limits, type:
FREQUENCY «input» LIMIT
then press
Enter
where «input» is described in
Table B-3
(default is all inputs)
A typical response from the TSG-3800 is:
TSG->FREQUENCY LIMIT
The Freq T100 Limit 1 for Inp2.1 is 50220
The Freq T100 Limit 2 for Inp2.1 is 24840
The Freq T100 Limit 1 for Inp3.1 is 50220
The Freq T100 Limit 2 for Inp3.1 is 24840
TSG->
Setting Frequency Fault Modes
To set a fault mode, type:
FREQUENCY «input» MODE [L1|L2] [FAIL|ALARM|REPORT|IGNORE]
then press
Enter
where «input» is described in
Table B-3
(default is all inputs)