Boiler Sequence Controller RMK770
CE1P3132en
HVAC Products
3 Commissioning
01.03.2005
N.
Y1
Y
RM
K7
70
N.
Q4
Q
N.
Q
1
Q
N.
Q2
Q
N.
Q
3
Q
N.
Q5
Q
N.
Q
6
Q
N.
Q7
Q
aa
d
d
d
d
1
2
3
4
5
6
Auto
a
DC 0...10 V
d
d
d
1.
2.
d
a
d
a
d
d
d
Q
QQ
Y
a
d
d
d
N1
N2
N.
X7
x
N.X
8
x
N.
X6
x
N.X
5
x
N.
X3
x
N.X
4
x
N.
X2
x
N.X
1
x
a
Q
d
d
B
d
B
V
Q
a
0...10 V
Y
d
d
d
d
Q
d
d
B
d
B
V
Q
a
N.
Y2
Y
0...10 V
Y
0...10 V
Y
2)
1)
2)
2)
1)
3P
3P
3P
3P
3P
3P
N.
D
1
d
N.
D
2
d
1.
2.
d
a
d
a
d
d
d
Q
QQ
Y
a
d
d
Q
d
d
B
d
B
V
Q
a
0...10 V
Y
d
0...10 V
Y
2)
2)
1)
3P
3P
A7
.Q
1
Q
A7
.Q
2
Q
A7
.Q
3
A7
.Q
5
3P
3132Z15
A7
.X
3
x
A7
.X
4
x
A7
.X
2
x
A7
.X
1
x
RM
Z7
87
(1
)
B
oil
er s
equ
en
ce
m
ana
ge
r
Main flow
Main return
Bo
ile
r-
se
qu
en
ce
se
lect
ion
Release
Constant
DHW
Frost prot.
Consumer return
(Water shortage) 1
(Overpressure) 2
(Underpressure) 3
MBRT return
close
open
H
ea
t re
qu
is.
Bo
ile
r 1
Mo
du
lati
ng
Shutoff valve
Flue gas
Burner
Curr burner outp
Setpoint comp.
St
ag
e
Release
Flue gas mode
(Water shortage) 1
(Overpressure) 2
(Underpressure) 3
Individual operation
Burner
close
open
Boiler
Return
close
open
dig.
dig.
Autonom
Shutoff valve
Bo
ile
r-
pu
m
p
MB
RT
Ma
in
pu
m
p
M
ain
t b
oile
r
re
turn
te
m
p
Bo
ile
r 2
Mo
du
lati
ng
Shutoff valve
Flue gas
Burner
Curr burner outp
Setpoint comp.
St
ag
e
Release
Flue gas mode
(Water shortage) 1
(Overpressure) 2
(Underpressure) 3
Burner
close
open
Boiler
Return
close
open
Shutoff valve
Bo
ile
r-
pu
m
p
MB
RT
The configuration diagram shows all function blocks active in the plant type. These are
the following function blocks in this example:
•
Boiler sequence manager
•
Boiler 1
•
Boiler 2
The configuration diagram shows the inputs and outputs that are preconfigured.
If required, additional inputs and outputs (e.g. flue gas temperature sensor, burner
operation checkback signal) can be assigned to the free inputs and outputs in the extra
configuration.
Also, it is possible to see which extension modules are required. For plant type K5.2,
extension module RMZ787(1) is used as standard. This is shown on the “Basic configu-
ration” menu, operating line "Position 1".
If required, the output for the first or the second boiler pump can also be configured to
some other output. It is also possible to change the type of extension module.
On function block “Boiler sequence manager“, the main flow temperature sensor (N.X1)
and the main return temperature sensor (N.X2) are preconfigured.
This can be checked on
Extra configuration > Boiler sequence manager > Inputs
.
On function block “Boiler 1“, the boiler temperature sensor is configured to terminal
N.X3. The burner is preconfigured to outputs N.Q2 and N.Q3, the boiler pump to
A7.Q1, and the shutoff valve to the relay with changeover contact N.Q1.
For boiler 2 – analogously – N.X6 is preconfigured for the boiler temperature sensor,
N.Q5 and N.Q6 for the 2-stage burner, N.Q4 for the shutoff valve, and A7.Q2 for the
boiler pump.
This can be checked on
Extra configuration > Boiler 1 (
or
b
oiler 2
)
> Inputs
(or
o
utputs
).
It is possible to reconfigure or remove preconfigured inputs and outputs. If, for example,
the second burner stage is removed from boiler 1 (---in place of N.Q3), the burner of
boiler 1 becomes a 1-stage burner.
Several function blocks can be activated in the extra configuration.
Function blocks
Inputs and outputs
Extension modules