11
– 26
(4)
Torque monitor
The counter monitor can be operated in two modes: arbitrary selection mode for monitoring
arbitrary seven counters; and designated subsequent number mode for monitoring 14
coupled counters. Either of two modes can be selected using the data selection auxiliary
register RWwn.
Arbitrary selection mode (RWwn = 0000H)
Monitoring up to seven arbitrary counters set to RWw(n+2, 4, 6, 8, A, C, E)
Monitor (CC-Link master station
CA20-M10-CC)
Response (CC-Link master station
CA20-M10-CC)
Remote
register
b15------b8
b7------b0
Remarks
Remote
register
b15------b8
b7------b0
Remarks
RWwn
00
H
00
H
Mode
selection
RWrn
00
H
03
H
Arbitrary selection
mode
*1
RWw(n+1)
Fixed at K0
Use
prohibited
RWr(n+1)
Fixed at K0
Use prohibited
RWw(n+2)
K1-K99
*2
Counter
number 1
RWr(n+2)
K1-K99
Counter number 1
RWw(n+3)
Fixed at K0
Use
prohibited
RWr(n+3)
K0-K9999
Value of counter
number 1
RWw(n+4)
K1-K99
*2
Counter
number 2
RWr(n+4)
K1-K99
Counter number 2
RWw(n+5)
Fixed at K0
Use
prohibited
RWr(n+5)
K0-K9999
Value of counter
number 2
RWw(n+6)
K1-K99
*2
Counter
number 3
RWr(n+6)
K1-K99
Counter number 3
RWw(n+7)
Fixed at K0
Use
prohibited
RWr(n+7)
K0-K9999
Value of counter
number 3
RWw(n+8)
K1-K99
*2
Counter
number 4
RWr(n+8)
K1-K99
Counter number 4
RWw(n+9)
Fixed at K0
Use
prohibited
RWr(n+9)
K0-K9999
Value of counter
number 4
RWw(n+A)
K1-K99
*2
Counter
number 5
RWr(n+A)
K1-K99
Counter number 5
RWw(n+B)
Fixed at K0
Use
prohibited
RWr(n+B)
K0-K9999
Value of counter
number 5
RWw(n+C)
K1-K99
*2
Counter
number 6
RWr(n+C)
K1-K99
Counter number 6
RWw(n+D)
Fixed at K0
Use
prohibited
RWr(n+D)
K0-K9999
Value of counter
number 6
RWw(n+E)
K1-K99
*2
Counter
number 7
RWr(n+E)
K1-K99
Counter number 7
RWw(n+F)
Fixed at K0
Use
prohibited
RWr(n+F)
K0-K9999
Value of counter
number 7
Data length of torque value: 32 bits
Unit of torque value: 0.01 [T] (Ex.: +2.00[T]
K+200)
T: Rating torque
It is impossible to monitor axis 2 to axis 4.
*1: The same value as the data selection check output signal RX(n+6)C to RX(n+6)F is
stored.
*2: The status values are stored at low byte.
High bytes are always fixed at 00.
Refer to section 11.3.3.3(1) for the status description.
Содержание CA20-M10
Страница 2: ......
Страница 14: ...XII 21 6 Spare parts 21 5 21 6 1 Controller spare parts 21 5 21 6 2 Axis spare parts 21 5...
Страница 24: ...1 10 This page is blank...
Страница 104: ...4 20 This page is blank...
Страница 112: ...5 8 This page is blank...
Страница 152: ...7 20 This page is blank...
Страница 190: ...10 20 This page is blank...
Страница 234: ...11 44 This page is blank...
Страница 244: ...12 10 This page is blank...
Страница 286: ...15 4 This page is blank...
Страница 300: ...17 12 This page is blank...
Страница 352: ...18 52 This page is blank...
Страница 382: ...21 6 This page is blank...
Страница 383: ......
Страница 384: ...Back cover Q3178E 03 APR 20...