64 . Clarus 590 GC User’s Guide
Setting Up Oven and Inlet Temperature Programs
The Clarus GC software allows you to set up to four-ramp programs (they are 0 [isothermal], 1, 2, or 3).
1.
From the System Status screen touch the
oven
icon
to modify the program.
2.
Once the oven program screen appears.
3.
Select a field by touching it and use the up and down arrow or keypad
buttons to
enter a temperature, equilibration time and rate. When the word END appears in the rate field all
the fields that follow are deactivated. You must touch END and then touch the plus (+) button to
activate the next row. The following figure shows a typical temperature step program.
Before you actually set up an oven temperature program, you should decide on the Equilibration Time you
need and change the default value (2 minutes) if necessary (see below).
Configuring the Equilibration Time (Init)
When you change the oven temperature setpoint, the system heats or cools the oven to the new setpoint,
then equilibrates the column(s) for the specified Equilibration Time before the instrument becomes READY.
NOTE: A minimum Equilibration Time of 2 minutes is recommended for temperature programs. Longer
equilibration times are recommended for initial oven temperatures of < 50°C. An equilibration time of 0.0
minutes can be used for isothermal methods.
Содержание CLARUS 590 GC
Страница 1: ...CLARUS 590 GC User s Guide GAS CHROMATOGRAPHY ...
Страница 9: ...About This Manual 9 Flame Ionization Detector FID 270 TCD 273 Autosampler 277 Index 279 ...
Страница 10: ...10 Clarus 590 GC User s Guide ...
Страница 11: ...1 Introduction ...
Страница 12: ...12 Clarus 590 GC User s Guide ...
Страница 21: ...2 Touch Screen Navigation ...
Страница 22: ...22 Clarus 590 GC User s Guide ...
Страница 48: ...48 Clarus 590 GC User s Guide PPC Active Method Configuration Screen Manual Pneumatics ...
Страница 50: ...50 Clarus 590 GC User s Guide PPC Active Method Configuration Screen Manual Pneumatics ...
Страница 59: ...3 Using the Active Method ...
Страница 60: ...60 Clarus 590 GC User s Guide ...
Страница 109: ...4 Setting Up the Detectors ...
Страница 110: ...110 Clarus 590 GC User s Guide ...
Страница 197: ...5 Using the Method Editor ...
Страница 198: ...198 Clarus 590 GC User s Guide ...
Страница 207: ...6 Using the Tools Menu ...
Страница 208: ...208 Clarus 590 GC User s Guide ...
Страница 224: ...224 Clarus 590 GC User s Guide ECD PID NPD FPD ...
Страница 225: ...Detectors 225 Output Configured ...
Страница 262: ...262 Clarus 590 GC User s Guide ...
Страница 263: ...7 Setting up a Typical Analysis ...
Страница 264: ...264 Clarus 590 GC User s Guide ...
Страница 279: ...Index ...
Страница 280: ...280 Clarus 590 GC User s Guide ...