Item
Data
NOTE
The data
configurati
on must be
the same as
the data
configurati
on on the
MGC.
paramet
ers
Media IP address and
signaling IP address
10.10.10.10/24
Default gateway IP address 10.10.10.1/24
MG interface ID
0
Signaling port ID
2944
IP address of the primary MGC
200.200.200.200/24
Port ID of the primary MGC
2944
Coding
Text
Transmission mode
UDP
H248 version that MG starts to
negotiate
1 (the negotiation starts from V1)
Voice user
configuratio
n data
Phone number
83110001-83110024
Terminal identification
Terminal layering is not supported
and the terminal identification
ranges from 0 to 23.
User priority
Cat2 for phone 1
Cat3 for phone 2 to phone 24
(default)
User type
Common user (DEL user by default)
Common
parameter
System parameter
Default value
Overseas parameter
Default value
PSTN port attribute
Polarity-reversal
Ringing current attribute
Default value
Procedure
Step 1
Log in to and configure the ONU.
You can remote log in to the ONU from the OLT to perform the configuration. The user name
is
root
and the password is
mduadmin
.
Step 2
Configure the upstream VLAN interface.
Specify the upstream VLAN interface for the media stream and the signaling flows and configure
the IP addresses of the Layer 3 interface. These IP addresses are the sources of the IP address
pools for the media stream and the signaling flows.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
870