huawei(config-if-gpon-0/1)#
ont confirm 0 ontid 2 sn-auth 6877687714852901 omci
ont-lineprofile-name
ftth ont-srvprofile-name ftth
NOTE
If multiple ONTs of the same type bound to the same line profile or service profile are connected to the same
port, you can bulk add ONTs by bulk confirming automatically discovered ONTs to make configuration
easier and more efficient. To do so, the preceding command can be modified as follows:
huawei(config-if-gpon-0/1)#
ont confirm 0 all sn-auth omci ont-lineprofile-name
ftth
ont-srvprofile-name ftth
l
(Optional) Bind the alarm profile to the ONT.
The default profile 1 is used in this example.
huawei(config-if-gpon-0/1)#
ont alarm-profile 0 1 profile-id 1
huawei(config-if-gpon-0/1)#
ont alarm-profile 0 2 profile-id 1
Step 3
Check ONT status.
After an ONT is added, run the
display ont info
command to query the current status of the
ONT. Ensure that
Config flag
of the ONT is
active
,
Run State
is
online
,
Config state
is
normal
, and
Match state
is
match
.
huawei(config-if-gpon-0/1)#
display ont info 0 1
---------------------------------------------------------------------
F/S/P : 0/1/0
ONT-ID : 1
Control flag :
active
//Indicates that the ONT is
activated.
Run state :
online
//Indicates that the ONT goes online
successfully.
Config state :
normal
//Indicates that the configuration state of the
ONT is normal.
Match state :
match
//Indicates that the capability profile bound to
the ONT is consistent with the actual capability of the ONT.
...//The rest of the response information is omitted.
When
Config state
is
failed
,
Run state
is
offline
, or
Match state
is
mismatch
:
l
If
Control flag
is
deactive
, run the
ont active
command in GPON mode to activate the ONU.
l
If
Run state
is
offline
, a physical line may be broken or the optical module may be damaged.
Check the line and the optical module.
l
If
Config state
is
failed
, the configured ONU capability exceeds the actual ONU capability.
In this case, run the
display ont failed-configuration
command in the diagnose mode to
check the failed configuration item and the failure cause. Then, rectify the fault accordingly.
l
If the ONU does not match, that is,
Match state
is
mismatch
, the port types and number of
ports undermatch the actual port types and number of ports supported by the ONU. In this
case, run the
display ont capability
command to query the actual capability of the ONU,
and then select one of the following modes to modify the ONU configuration:
–
Create a proper ONU profile according to the actual capability of the ONU, and then run
the
ont modify
command to modify the configuration data of the ONU.
–
Modify the ONU profile according to the actual capability of the ONU and save the
modification. Then, the ONU automatically recovers the configuration successfully.
----End
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
9 FTTH Configuration
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
662